Brookvent Aircycle 3.1/4.1 Front Panel Kit
Product Code: AS 90-09-810
Please indicate in the order notes which version you need (e.g. 3.1 or 4.1)
A Brookvent Aircycle 1.2,1.3 and 1.3+Replacement Wall Bracket Kit. Product Code: AS 90-09-909
The unit should be attached to the wall using the wall bracket provided, please ensure the mounting surface can safely bear the load of the unit using suitable screw fixings.
Step by Step Instructions for Wall Mount:
Remove the existing bracket which will be secured to the back of the unit and replace with new one.
The second bracket should be secured to the mounting surface (wall) Please ensure the brackets are level.
The unit can then be set onto the mounting surface with the lip of each bracket
Ensure the system is level when fully mounted.
Ensure the unit is fully attached and secure.
If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk
https://brookvent.co.nz/product/aircycle-1-3-house-ventilation-system/
$21.00 + GST
Brookvent Aircycle 3.1/4.1 Front Panel Kit
Product Code: AS 90-09-810
Please indicate in the order notes which version you need (e.g. 3.1 or 4.1)
Brookvent Aircycle 3.1 Dial operated PCB kit.
In the unlikely event of an electronic PCB failure, the Aircycle 3.1’s PCB module can be easily disconnected and replaced. Product Code: AS 90-09-801
Step By Step Process:
Step 1. Isolate the unit from the mains and ensure all supply circuits are disconnected.
Step 2. Disconnect the mains from the fused spur.
Step 2. Unscrew the two large screws in the front of the control panel and pull out the PCB assembly.
Step 3. Unplug all the leads, the connectors are all marked to match up with their corresponding internal connections.
Step 4. Feed the mains cable from the replacement assembly through the unit and out the through the hole in the back plate.
Step 5. Connect all the cables back up ensuring to connect each cable to the correctly marked connector.
Step 6. Replace the assembly in the pocket and secure in place with the screws.
Step 7. Connect the mains to the fused spur.
Step 8. Power the unit on at the isolator and ensure any supply circuits are reconnected. The unit will need to be re-commissioned.
Brookvent Aircycle 1.2/1.3/1.3+ Filter Cover Set (AS 90-09-908)
These replacement covers are the front cover tabs that protect your MVHR filters.
Product Code: (AS 90-09-908)